Sensa Core / Blood Gas Analyzers

ST 200 CC Smart Blood Gas Analyzer

Blood Gas Analyzers

Machines & equipment

This next-generation Hybrid device represents a significant leap forward in efficiency, accuracy, and connectivity for critical blood gas and electrolyte analysis, as it combines conventional long-lasting maintenance-free ISE electrodes along with thick film technology for Hematocrit , metabolites ( Glucose and Lactate ) and Dissolved Oxygen.

01 / A CLOSER LOOK

Features that
define the product.

  • Principle: Direct Measurement with ISE(electrolytes), Impedance (Hct), and Amperometry (Gases and Metobolites) with Thick film Technology
  • Parameters: Blood Gas: pH, PCO2, pO2 Electrolytes: Na, K, Li, Cl, iCa Hematocrit: Hct Metabolites: GLU, LAC Calculated Parameter: Hb, HCO3, BE, BE-B, BE-ECF, TCO2, AG, AG(K), O2 Sat, O2 Ct, SBC, nCa, TCa, pO2%, A, AaDO2, a/A. mOsm
  • Sample volume: 100 μL (Capillary/Micro mode)
  • Throughput: 30 Results
  • Result time: 120 sec
  • Display: 10-inch High definition LCD Screen

02 / HOW IT WORKS

The technology.

Direct Measurement with ISE(electrolytes), Impedance (Hct), and Amperometry (Gases and Metobolites) with Thick film Technology

03 / TECHNICAL DETAILS

Specifications.

Manufacturer-listed information
Sample Volume100 μL (Capillary/Micro mode)
Resultswith 1 Sample 27 different results (11 different measuring parameter results along with 17 different calculated parameter results)
Sample TypeWhole Blood, Serum, Plasma, Diluted Urine and QC
ParametersBlood Gas: pH, PCO2, pO2 Electrolytes: Na, K, Li, Cl, iCa Hematocrit: Hct Metabolites: GLU, LAC Calculated Parameter: Hb, HCO3, BE, BE-B, BE-ECF, TCO2, AG, AG(K), O2 Sat, O2 Ct, SBC, nCa, TCa, pO2%, A, AaDO2, a/A. mOsm
External IntegrationBarcode Scanner, Mouse, Keypad (Any 2 at a Time) & LIS Integration (Serial Port)
Internal Bar Code ScannerNot Available
Dimensions15.2" W x 13.2" H x 8.3" D
Weight5 kg
ColourWhite
Pump MechanismLong-Lasting Comprehensive Lyte
Sample Storage1,00,000
Language/s94+ Languages
PrincipleDirect Measurement with ISE(electrolytes), Impedance (Hct), and Amperometry (Gases and Metobolites) with Thick film Technology
Parameter Combinations11 Combinations
Touch ScreenAvailable (Capacitive Touch)
Operating SystemAndroid
External BatteryAvailable (Optional)
Input Voltage110/115-V AC, 50-60 Hz or 220V AC, 50-60 Hz, 0.75 amp
Operating AtmosphereTemperature: 10 - 30 Degrees C, <85% Moisture
Print Result3 Inch Column Thermal Printer
Acquirable Results / Hour30 Results
Result Time120 sec
Sample MechanismSemi-Auto Sampling
Display10-inch High definition LCD Screen

04 / KEEP THE DETAILS

Documents.